SK0-005 Dumps

SK0-005 Free Practice Test

CompTIA SK0-005: CompTIA Server+ Certification Exam

QUESTION 26

An administrator is configuring the storage for a new database server, which will host databases that are mainly used for archival lookups. Which of the following storage types
will yield the fastest database read performance?

Correct Answer: B
The storage type that will yield the fastest database read performance is SSD. SSD (Solid State Drive) is a type of storage device that uses flash memory to store data. SSDs have no moving parts and can access data faster than traditional hard disk drives (HDDs) that use spinning platters and magnetic heads. SSDs are especially suitable for databases that are mainly used for archival lookups, as they can provide faster response times and lower latency for read operations.
References: CompTIA Server+ SK0-005 Certification Study Guide, Chapter 1, Lesson 1.2, Objective 1.2

QUESTION 27

An administrator is troubleshooting a server that is rebooting and crashing. The administrator notices that the server is making sounds that are louder than usual. Upon closer inspection, the administrator
discovers that the noises are coming from the front of the chassis. Which of the following is the most likely reason for this behavior?

Correct Answer: A
A server has multiple fans inside the chassis to cool down the components and prevent overheating. If one of the fans fails, it can cause the server to reboot and crash due to thermal issues. A failed fan can also make loud noises due to friction or vibration. The administrator should check the fans and clean them from dust and debris, or replace them if they are damaged12.
References = 1: It’s Too Loud! 3 Solutions to Remedy Server Noise - Computerware Blog | DC Metro | Computerware Blog(https://www.cwit.com/blog/it-s-too-loud-3-solutions-to-
remedy-server-noise) 2: What factors affect the noise level of a server? - Server Fault(https://serverfault.com/questions/430550/what-factors-affect-the-noise-level-of-a-server)

QUESTION 28

An application server cannot communicate with a newly installed database server. The database server, which has static IP information, is reading the following output from ipconf ig:
SK0-005 dumps exhibit
The application server is reading the following output from ipconf ig:
SK0-005 dumps exhibit
Which of the following most likely contains an error?

Correct Answer: D
The subnet mask is most likely containing an error that prevents the application server from communicating with the newly installed database server. The subnet mask is a binary number that defines how many bits of an IP address are used for the network portion and how many bits are used for the host portion. The subnet mask determines which devices belong to the same network or subnet and can communicate directly with each other without routing or switching devices. The subnet mask of the database server is 255.255.O.O, which means that all 32 bits of its IP address are used for the network portion and none for the host portion, which is invalid and makes it unreachable by any other device on any network or subnet. The subnet mask of the application server is 255.O.O.O, which means that only 8 bits of its IP address are used for the network portion and 24 bits are used for the host portion, which is also uncommon and makes it incompatible with most networks or subnets. References: [CompTIA Server+ Certification Exam Objectives], Domain 4.0: Networking, Objective 4.1: Given a scenario, configure network settings for servers.

QUESTION 29

A server administrator is deploying a new server that has two hard drives on which to install the OS. Which of the following RAID configurations should be used to provide redundancy for the OS?

Correct Answer: B
RAID 1 (mirroring) is a RAID configuration that should be used to provide redundancy for the OS on a server that has two hard drives on which to install the OS. RAID 1 (mirroring) is a configuration that duplicates data across two or more drives. It provides fault tolerance and improves read performance, but reduces storage capacity by half. If one drive fails in RAID 1, the other drive can continue to operate without data loss or system downtime. RAID 0 (striping) is a configuration that splits data across two or more drives without parity or redundancy. It improves performance but offers no fault tolerance. If one drive fails in RAID 0, all data is lost and the system cannot boot. RAID 5 (striping with parity) is a configuration thatstripes data across three or more drives with parity information. It provides fault tolerance and improves performance, but reduces storage capacity by one drive’s worth of space. RAID 5 can tolerate one drive failure without data loss, but not two or more. RAID 6 (striping with double parity) is a configuration that stripes data across four or more drives with double parity information. It provides fault tolerance and improves performance, but reduces storage capacity by two drives’ worth of space. RAID 6 can tolerate two drive failures without data loss, but not three or more.References:https://www.howtogeek.com/199068/how-to-upgrade-your-existing-hard-drive-in-under-an-hour/

QUESTION 30

A company is implementing a check-in desk to heighten physical security. Which of the following access controls would be the most appropriate to facilitate this implementation?

Correct Answer: D
An access control vestibule, or mantrap, is a type of physical access control that provides a space between two sets of interlocking doors. It is designed to prevent unauthorized individuals from following authorized individuals into facilities with controlled access, such as a check-in desk. The vestibule can be configured to limitthe number of individuals who enter the controlled area and to verify their authorization for physical access1. The other options are incorrect because they are not as effective as an access control vestibule in
facilitating the implementation of a check-in desk. Security guards, security cameras, and bollards are useful for monitoring, deterring, or preventing unauthorized access, but they do not provide the same level of control and verification as an access control vestibule