Due to a planned power outage, an administrator decides to shut down the vSAN cluster using the Shutdown Cluster Wizard. The administrator starts by checking the vSAN health service to confirm the cluster is healthy and then powers off all virtual machines (VMs) including vCLS VMs.
Which step needs to be taken before starting the Shutdown Cluster Wizard?
Correct Answer:
C
To shut down the vSAN cluster using the Shutdown Cluster Wizard, the administrator needs to turn off High Availability (HA) before starting the wizard. This is because HA monitors the cluster for host failures and attempts to restart the affected VMs on other hosts. If HA is not turned off, the cluster might register host shutdowns as failures and trigger unnecessary VM restarts, which can interfere with the graceful shutdown process. Therefore, the administrator should disable HA from the Configure tab of the cluster before using the Shutdown Cluster Wizard12 References: 1: Shut Down the vSAN Cluster Using the Shutdown Cluster Wizard 3 2: Manually Shut Down and Restart the vSAN Cluster 4
What is the purpose of host rebuild reserve in vSAN?
Correct Answer:
B
The host rebuild reserve is a feature that allows vSAN to reserve space in the cluster for vSAN to be able to repair in case of a single host failure. This reservation is set to one host worth of capacity, which means that if one host in the vSAN cluster fails and no longer contributes storage, there is still sufficient capacity remaining in the cluster to rebuild and re-protect all vSAN objects. This feature prevents the creation of new VMs or powering on VMs if such operations consume the reserved space. By default, the host rebuild reserve is disabled, but it can be enabled in the vSAN Services configuration. The other options are not related to the hostrebuild reserve. References: vSAN Capacity Management in v7.0U1; Configure Reserved Capacity
Which two actions are recommended when adding a host to a vSAN cluster? (Choose two.)
Correct Answer:
AE
When adding a host to a vSAN cluster, it is recommended to create uniformly-configured hosts and reference the VMware Compatibility Guide. These actions will ensure that the host meets the hardware and software requirements for vSAN, and that it can work seamlessly with the existing hosts in the cluster. Uniformly-configured hosts have the same number and type of disk groups, cache devices, capacity devices, network adapters, and drivers. The VMware Compatibility Guide provides a list of certified components and firmware versions that are compatible with vSAN. The other options are not recommended, as they can cause disruption or degradation of the vSAN cluster services. Disabling vSAN performance service, vSphere Cluster Services, or vSphere High Availability (HA) can affect the monitoring, availability, and load balancing of the cluster.
An administrator is performing maintenance on the hosts in a four-node vSAN cluster and has selected the "Ensure Accessibility" maintenance mode option. All VMs are running with the Default Storage Policy which has not been modified from the default settings.
While one of the hosts in the cluster is down for firmware upgrade, a second host suddenly loses network connectivity to the remaining hosts.
How will the cluster be affected?
Correct Answer:
A
If two hosts in a four-node vSAN cluster are down, the cluster might experience data loss because the default storage policy has a Primary level of failures to tolerate (PFTT) of 1, which means that vSAN can tolerate only one host failure. The Ensure accessibility maintenance mode option does not guarantee full data redundancy, but only ensures that all accessible VMs remain accessible. If another host fails while one host is in maintenance mode, some VMs might lose access to their data components and become unavailable or corrupted. References: vSAN Maintenance Mode Options; vSAN Cluster Configuration Limits
During yesterday's business hours, a cache drive failed on one of the vSAN OSA nodes. The administrator reached out to the manufacturer and received a replacement drive the following day. When the drive failed, vSAN started a resync to ensure the health of the data, and all objects are showing a healthy and compliant state. The vSAN administrator needs to replace the failed cache drive.
Which set of steps should the vSAN administrator take?
Correct Answer:
C
To replace a failed cache drive in a vSAN OSA cluster, the vSAN administrator should remove the existing vSAN disk group and physically replace the device. Then check to verify that the ESXi host automatically detects the new device Afterwards manually recreate the Disk Group. This is because when a cache drive fails, it affects the entire disk group that contains it, and vSAN does not allow removing only the cache drive from a disk group. Therefore, the administrator must remove the whole disk group before replacing the cache drive, and then recreate it with the new cache drive and the existing capacity drives. The other options are not correct. Physically replacing the failed cache drive without removing the disk group first might cause errors or inconsistencies in vSAN configuration. vSAN will not automatically create a new disk group or allocate storage after replacing a cache drive, as these actions require manual intervention from the administrator. Rebalancing the cache layer is not necessary after replacing a cache drive, as vSAN will automatically distribute data across all devices in the disk group. References: Replace a Flash Caching Device on a Host; How to manually remove and recreate a vSAN disk group using esxcli