A vSphere administrator has deployed a new server. The VM will have a workload which is prodApp1 to the following specifications:
• The VM should never have any memory contention while powered on. even if the host that it resides
• Configure the virtual machine for high latency sensitivity.
Send us your suggestions.
Solution:
Does this meet the goal?
Correct Answer:
A
The current vSphere environment will be adding new ESXi hosts that will be used to create a QA compute cluster. This cluster should have HA properties specific to the workloads that will be running in it.
In preparation of adding the new hosts, create the new cluster. QA-Cluster in. Datacenter-PROD on vcsa0la.vclass.local with the following HA requirements:
• The cluster should not contain any ESXi hosts or VMs
• Hosts should be monitored.
• VMs should be restarted in the event of a host failure.
• VMs should be restarted if guest heartbeats are not detected.
• In the case of a host becoming isolated, shutdown and restart VMs.
• If there is an All Paths Down event, any affected VMs must be moved to another host.
• Reserve 10% of memory and CPU for failover capacity.
Part 2
You have been given a requirement for a virtual machine to have no downtime when an ESXi host failure occurs. Configure Fault Tolerance on VM1-FT in the PROD-B cluster. Use any compatible secondary host and datastore. Configure the following advanced cluster settings. Use SAN01 as the storage during configuration.
das.isolationaddress0 172.20.10.11
dass.igoreRedundantNetWarining true
Note: ignore any related host, customer, or bandwidth warnings as long as fault tolerance is configured and VM1-FT is running.
Send us your suggestions.
Solution:
Does this meet the goal?
Correct Answer:
A
The IT Team recently implemented a Unified Communication Service to provide conferencing for the organization. The UCS Application server is running from a virtual machine named VM1-UCS. Due to the nature of the UCS. the traffic for VM1-UCS has a higher Class of Service (CoS) demand.
In order to meet demand bandwidth for VM1 hosting the UCS. you been have given the task to improve performance by isolating the traffic and configuring CoS for this VM.
Your first task is to connect VM1-UCS to the distributed port group. UCS-Portgroup.
Your second task is to tag and mark the traffic for VM1-UCS with the following parameters:
• Name: UCS Network Traffic
• CoS Value: 4
• DSCP Value: 34
• Traffic Direction: Ingress/Egress
• Traffic Qualifier: System Traffic - Virtual Machine
The IT Team noticed that some of the parameter where not available on the distributed switch. Troubleshoot why these settings are missing and fix it.
Send us your suggestions.
Solution:
Does this meet the goal?
Correct Answer:
A